Indoor unit for the production of chilled water combined with a remote condenser, with semi-hermetic screw compressors optimized for R134a, shell and tube evaporator designed by Mitsubishi Electric Hydronics & IT Cooling Systems S.p.A. and thermostatic expansion valve.
Base and supporting structure and panels are of galvanized epoxy powder coated steel with increased thickness.
Flexible and reliable unit; it easily adapts itself to different thermal load conditions thanks to the precise thermoregulation. The high performance’s level is achieved thanks to the accurate sizing of all internal components.
Compactness in terms of overall size and weight, improving installation and on-site maintenance.
ADAPTABILITY
Can adapt to the building’s cooling request thanks to the continuous capacity regulation, assured by the control's sophisticated logic.
WIDE OPERATING RANGE
Extensive range of operation with remote condenser operating up to 46°C air temperature
SILENT OPERATION
Extremely silent operation thanks to the unit's accurate design. Optional integral acoustic enclosure, further reduces the sound level beyond the best on market
Technical data
Technical data
Produkt-Informationen
Produkt-Informationen
B - Basic
Soft start
Set-up for remote connectivity with ModBus, Echelon, Bacnet, Bacnet over-IP.
Remote control keyboard (distance 200m and 500m)
Electronic expansion valve
Integral acoustical enclosure (base or plus)
W3000SE Large
The W3000 SE Large controller offers advanced functions and algorithms.
The keypad is generously sized with full operating status display. The commands and detailed LCD display make access to the unit’s settings easy and safe. These resources allow one to consult and intervene on the unit by means of a multi-level menu, with selectable language settings.
The diagnostics includes a complete alarm management, with the "black-box" and alarm logging functions for enhanced analysis of the unit operation.
For a multiple unit systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Echelon LonWorks.
Compatibility with the remote keyboard to manage up to 10 units.
Availability of an internal real time clock for operation scheduling (4-day profiles with 10 hour belts).
The regulation features the continuous modulation of capacity, based on a dynamic dead band and referring to the leaving water temperature. As alternative, step-wise regulation is also available, referred to the return water temperature with selectable proportional- or proportional-integral logic.