NX-WN-Y 0122 - 1004

image
Reversible heat pump, water source 37,5 - 306 kW
Water to water indoor unit for the production of chilled/hot water with hermetic rotary Scroll compressors, braze-welded plate-type exchanger, and electronic expansion valve. Base and frame in hot-galvanized shaped steel sheets with a suitable thickness. All parts polyester-powder painted to ensure total weather resistance, RAL 7035. The range includes the single-circuit two-compressor versions and the dual circuit four-compressor versions.
EUROPE
CE
50 Hz

Product features

Features
HIGH EFFICIENCY
Very high efficiency at full and partial loads, at the highest market levels, thanks to the adopted technological solutions. These units ensure low operating costs and therefore a quick payback time.
ErP READY
The highest level of efficiency at part load can meet and exceed the minimum seasonal efficiency for heating, SCOP (only for reversible units) and for process cooling, SEPR, in accordance with the eco-sustainable design requirements for all products using energy.
VARIBLE PRIMARY FLOW (OPTION)
Energy savings due to variable pump speed management based on load demand and the variable flow assures the functioning of the units also with critical working conditions. VPF (Variable Primary Flow) available for sizes 0604-1204.
EXTREMELY SILENT OPERATION
Extremely silent operation together with high efficiency, thanks to dedicated acoustic devices and a precise design for the choice of the components.
INTEGRATED HYDRONIC MODULE
The built-in hydronic module already contains the main water circuit components; it is available as option with single or twin in-line pump, for achieving low head, fixed or variable speed, available for user side and source side (up to 4 pumps).
INTEGRATED CONDENSATION CONTROL
The electronics of the units manages the most suitable condensing control for each type of application: pressure-controlled valve, two or three-way modulating valve, 0-10V signal for variable speed driven pumps.
TOTAL VERSATILITY
The units have been designed with a range of integrated accessories, keeping in mind the operation with open loop (well water or ground water), dry cooler, or cooling tower and they are suitable for geothermal application so as to satisfy all service systems and installation requirements.
ELECTRONIC EXPANSION VALVE SUPPLIED STANDARD
The use of the electronic expansion valve generates considerable benefits, especially in cases of variable demand and at different working conditions. It guarantees energy savings due to efficiency optimization in various different working conditions which translates into a reduction in operating consumption, a faster start-up of the unit and a wider extension of the operating limits.

Technical data

Technical data

Produkt-Informationen

Produkt-Informationen
  • - - Standard efficiency
  • - - Basic function
  • Touch Screen visual display
  • Set-up for remote connectivity with ModBus/Echelon protocol cards
  • Outside air temperature probe for plant water set point compensation.
  • Integral acoustical enclosure (type base)
  • Thicker soundproofing insulation
  • User side and source side hydronic kit available in different configurations
  • VPF (Variable Primary Flow) system
  • Condensing control device: two or three-way modulating pressure-controlled valve and inverter on pumps

Electronic control W3000TE

The W3000 Compact keypad provided as standard, features control functions and a complete LCD display for viewing data and activating the unit, via a multi-language menu. In alternative or in addition to the keyboard, the innovative user interface KIPlink allows one to operate on the unit directly from a smartphone or tablet. Using KIPlink, it is possible to turn the unit on and off, adjust the set-point, plot the main operating variables, monitor the status of the refrigerant circuits, the compressors, the fans and the pumps (if present), and display and reset possible alarms. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, beneficial in low water content systems. Alternatively, proportional or proportional- integral regulations are also available. A complete alarm management system is available, with a “black-box” and the alarm history display functions. For a multiple unit systems, the regulation of the resources can be implemented via optional proprietary devices. Energy metering, for both consumption and capacity, can also be developed. The built-in clock can create an operating profile up to 4 typical days and 10 time bands. Supervision is available either using proprietary devices or by integration into third party systems using ModBus, BACnet, BACnet-over-IP and Echelon LonWorks protocols. A dedicated wall-mounted keypad can be used for remote control of all functions. Optionally (VPF package), capacity modulation can be integrated with hydraulic flow modulation, thanks to inverter-driven pumps and to specific resources for the hydraulic circuit.

Downloads

Downloads
Application brochure
Application brochure PHARMACEUTICAL INDUSTRY EN
Application brochure FOOD INDUSTRY EN
Application brochure WINERY EN
Application brochure DISTRICT HEATING BUSINESS EN
Informative data act
Informative data act Applied Remote Suitcase EN
Informative data act RUT140 EN
Informative data act W3000+ EN
Informative data act W3000Touch+ EN
Informative data act Touch Room HMI EN
Informative data act KIPLink EN
Product overview
Product overview PROCESS OVERVIEW EN
Technical documentations - regulation (EU) N. 2015/1095
Technical documentations - regulation (EU) N. 2015/1095 NX-WN-Y 0122 - 1204 SEPR-HT EN
Installation, user and maintenance manual (IUM)
R454B supporting documents
R454B supporting documents R454B MANUAL EN
Energy label UK
Energy label UK NX-WN-Y EN
Energy label EU
Energy label EU NX-WN-Y EN